Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Trauma ; 37(5): 222-229, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36821478

RESUMO

OBJECTIVE: To compare fracture patterns and associated injuries for young patients with high- versus low-energy intertrochanteric hip fractures and to report on factors associated with complications after surgical fixation of high-energy fractures. DESIGN: Retrospective comparative study. SETTING: Academic Level 1 Trauma Center. PATIENTS: A total of 103 patients 50 years of age or younger were included: 80 high-energy fractures and 23 low-energy fractures. INTERVENTION: Cephalomedullary nailing (N = 92) or a sliding hip screw (N = 11). MAIN OUTCOME MEASURES: Radiographic characteristics of fracture morphology, implant position, and reduction quality and postoperative complications were the main outcome measures. RESULTS: Compared with young patients with low-energy fractures, those with high-energy fractures had more fracture comminution ( P = 0.013) and higher ISS scores ( P < 0.003) and were more likely to require open reduction ( P < 0.001). Patients with low-energy fractures from a ground-level fall had higher rates of alcohol abuse (0.032), cirrhosis (0.010), and chronic steroid use (0.048). Overall reoperation rate for high-energy fractures was 7%, including 2 IT fracture nonunions (5%) and 1 deep infection (2%). For high-energy fractures, ASA class ( P = 0.026), anterior lag screw position ( P = 0.001), and varus malreduction ( P < 0.001) were associated with malunion. Four-part fracture (OTA/AO 31A2.3/Jensen 5) ( P = 0.028) and residual calcar gap >3 mm ( P = 0.03) were associated with reoperation. CONCLUSIONS: Surgical treatment of high-energy IT fractures in young patients is technically demanding with potential untoward outcomes. Injury characteristics and severity are significantly different for young patients with high-energy IT fractures compared with low-energy fractures. For young patients with a high-energy IT fracture, surgeons can anticipate a high rate of associated injuries and complex fracture patterns requiring open reduction. For young patients with a low-energy IT fracture, comanagement with a hospitalist or a geriatrician should be considered because they may be physiologically older. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Pinos Ortopédicos , Parafusos Ósseos/efeitos adversos , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
2.
J Orthop Trauma ; 37(2): 77-82, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36001894

RESUMO

OBJECTIVE: To determine whether a reduced secondary operation rate offsets higher implant charges when using suture button fixation for syndesmotic injuries. DESIGN: Retrospective cohort study. SETTING: Single, urban, Level 1 trauma center. PARTICIPANTS: Three-hundred twenty-seven (N = 327) skeletally mature patients with rotational ankle fractures (OTA/AO type 44) necessitating concurrent syndesmotic fixation. INTERVENTION: Suture button or solid 3.5-mm screw syndesmotic fixation. MAIN OUTCOME MEASUREMENTS: To compare implant charges with secondary operation charges based on differential implant removal rates between screws and suture buttons. RESULTS: Patients undergoing screw fixation were older (48.8 vs. 39.6 years, P < 0.01), had more ground-level fall mechanisms (59.3% vs. 51.1%, P = 0.026), and sustained fewer 44C type injuries (34.7% vs. 56.8%, P = 0.01). Implant removal occurred at a higher rate in the screw fixation group (17.6% vs. 5.7%, P = 0.005). Binomial logistic regression identified nonsmoker status (B = 1.03, P = 0.04) and implant type (B = 1.41, P = 0.008) as factors associated with implant removal. Adjusting for age, the NNT with a suture button construct to prevent one implant removal operation was 9, with mean resulting additional implant charges of $9747 ($1083/case). Backward calculations using data from previous large studies estimated secondary operation charges at approximately $14220, suggesting a potential 31.5% cost savings for suture buttons when considering reduced secondary operation rates. CONCLUSIONS: A reduced secondary operation rate may offset increased implant charges for suture button syndesmotic fixation when considering institutional implant removal rates for operations occurring in tertiary care settings. Given these offsetting charges, surgeons should use the syndesmotic fixation strategy they deem most appropriate in their practice setting. LEVEL OF EVIDENCE: Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Humanos , Estudos Retrospectivos , Traumatismos do Tornozelo/cirurgia , Fraturas do Tornozelo/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Tornozelo/cirurgia , Técnicas de Sutura , Suturas
3.
J Surg Orthop Adv ; 29(3): 135-140, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33044152

RESUMO

The purpose is to evaluate hip fractures due to gunshot wounds (GSW) to the hip, which are treated surgically, and the complications. Patients who sustained a low velocity GSW with fracture to the femoral head/neck and intertrochanteric/peritrochantric region at three Level 1 Trauma Centers were eligible. There were 69 patients (63 males-91%), with an average age of 29 (18-60). Nine patients had orthopaedic surgical site infections. There were 6 nonunions, 4 patients with hardware failure, 2 cases of avascular necrosis (AVN), 3 patients with post traumatic arthritis (PTA) and 20 patients with heterotopic ossification (HO). There was no significant difference found regarding fracture site or type of fixation with regards to complications. This represents the largest study of surgically treated GSW to the hip. Of patients studied, 61% sustained additional GSW. These injuries are not benign; the main complications being infection and heterotopic ossification. (Journal of Surgical Orthopaedic Advances 29(3):135-140, 2020).


Assuntos
Fraturas do Quadril , Ferimentos por Arma de Fogo , Adulto , Cabeça do Fêmur , Fixação Interna de Fraturas , Fraturas do Quadril/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/cirurgia
4.
Orthopedics ; 39(5): e997-e1000, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27337668

RESUMO

Calcific tendinitis is a relatively rare condition in which calcium is inappropriately deposited in tendons, resulting in a local inflammatory reaction that can cause severe symptoms in certain cases. The cause of this disease process is not completely understood, although repetitive microtrauma likely plays a role in its development. Although the disorder most often involves the rotator cuff, it can affect other structures throughout the body, such as the tendons about the ankle and hip-including the rectus femoris and gluteus maximus. Nonoperative management typically involves using an anti-inflammatory medication and activity modification and can be augmented with formal physical therapy and modalities. Although nonoperative management provides adequate relief for many patients, sometimes operative debridement of the calcific deposit with or without repair of the involved tendon is required. The authors report an unusual case of calcific tendinitis of the gluteus maximus insertion in a golfer. The patient had tried nonoperative treatment for approximately 2 years with no real relief, and a recent exacerbation of the pain was significantly delaying his return to sport. Although plain radiographs did not show abnormalities, magnetic resonance imaging showed a calcific deposit in the insertion of the gluteus maximus tendon. After discussing further treatment options with the patient, the decision was made to remove the deposit and repair the insertion. He recovered completely and was able to return to play. The frequency, pathogenesis, and treatment of this condition are discussed in this case report, as well as the possible link to golf in this patient. [Orthopedics.2016; 39(5):e997-e1000.].


Assuntos
Calcinose/diagnóstico , Transtornos Traumáticos Cumulativos/diagnóstico , Golfe/lesões , Tendinopatia/diagnóstico , Adulto , Nádegas , Calcinose/etiologia , Calcinose/cirurgia , Transtornos Traumáticos Cumulativos/etiologia , Transtornos Traumáticos Cumulativos/cirurgia , Humanos , Masculino , Tendinopatia/etiologia , Tendinopatia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...